HX711 24-Bit Load-Cell Amplifier and 20 kg Sensor Bundle

80,00 DH

Availability:

105 in stock

Availability:

298 in stock

Availability:

105 in stock

SKU: 0226-GRP Categories: ,

Description

HX711 Load-Cell Amplifier and 20 kg Sensor Bundle

Bundle comprising an HX711 load-cell amplifier module and a 20 kg load cell for bridge-sensor weighing projects.

Bundle contents

  • 1 × HX711 amplifier and 24-bit ADC module
  • 1 × 20 kg load cell

HX711 module specifications stated in the source

  • Supply: 2.6–5.5 V
  • Normal current: under 1.5 mA; standby: under 1 µA
  • 24-bit conversion; two selectable differential input channels
  • Low-noise PGA gain: 32, 64 or 128
  • Selectable output rate: 10 or 80 SPS
  • Simultaneous 50/60 Hz supply rejection
  • Integrated regulator, oscillator and power-on reset

Load-cell specifications stated in the source

  • Rated capacity: 20 kg
  • Rated output: 1.0 mV/V ±0.15 mV/V; zero balance: ±0.1 mV/V
  • Repeatability: 0.03% FS; creep: 0.03% FS (source gives 5 minutes for the bundle listing)
  • Input impedance: 1115 Ω ±10%; output impedance: 1000 Ω ±10%
  • Safe overload: 150% FS; ultimate overload: 200% FS
  • Material: aluminum alloy; protection class listed: IP65
  • Operating temperature listed: −20 to +85 °C
  • Price: MAD 80

Load-cell wire colors shown in the source

  • Red: E+ (excitation +)
  • Black: E− (excitation −)
  • Green: A+ (signal +)
  • White: A− (signal −)

HX711 load-cell wiring diagram

Supply note: the source lists 2.6–5.5 V for the HX711 module and 3–15 V as a recommended operating voltage for the load cell. These are component ratings; the module supply must stay within the HX711 board’s rating. Check the exact board wiring and ratings before applying power. Do not exceed the load cell’s rated capacity.