Description
MAX6675 Type-K Thermocouple-to-Digital Converter Module
Breakout module built around the MAX6675, which digitizes a Type-K thermocouple signal and provides a 12-bit SPI-compatible output with cold-junction compensation.
Specifications listed
- Supply: 3.0–5.5 V
- Typical operating current: 50 mA
- 3-wire SPI digital output
- 12-bit temperature data; 0.25 °C resolution
- Integrated cold-junction compensation and thermocouple detection
- MAX6675 conversion range listed by the source: 0–1024 °C
- Price: MAD 60
The source’s separate Type-K probe listing gives a 0–600 °C range. Temperature range and accuracy depend on the probe and conditions; consult the MAX6675 datasheet.